Position Sensors
Position Sensors
Linear position sensors measure, via a proportional electrical output, a physical position. They are used to provide feedback (data) for position measuring or automation control systems. Proheat provides to types of sensing technologies: Linear Potentiometers, and Magnetostrictive.
Linear Potentiometers , also known as “Pots”, employ a resistive trace and contact wiper that provides an output based on the wipers position along the trace. The following Product Series use this technology: LT, PC, PK, PA1, PY1-3, PZ12, PZ34, PMA12, PME12, PMI12, and IC Series.
Magnetostrictive technology uses a non-contact technology based on magnetic principles. Since there is no physical contact between the cursor and the measuring track, this technology has a theoretical unlimited lifetime. The non-contact technology not only provides high resolution and superior reliability, but an array of choices for signal outputs. The following Product Series use this technology: MK, and IK.
LT Rectilinear Displacement Transducer
| Main features:
• 50 to 900 mm stroke.
• Mechanical linkage using M6 thread
• Independent linearity ± 0.05%
• Repeatability 0.01 mm.
• Infinite resolution
• No variation of electrical signal outside theoretical electrical stroke
• Displacement speed up to 5 m/s (optional 10m/s)
• Working temperature: -30…+100°C
• Electrical connections:
- LT M 4 pole connector to standard DIN43650 ISO4400
- LT B 5 pole connector DIN43322
- LT F 3 pole screened cable (1m length).
• Life duration: > 25×106 meters or > 100×106 operations whichever is the smaller (within C.E.U.)
• Grade of protection IP60 (optional IP65) |
 |
PK Rodless Rectilinear Displacement Transducer
| Main features:
• 100 to 2000 mm. stroke
• Mechanical linkage using joint with take up of play, M5 thread
• Independent linearity up to ± 0.05%
• Repeatability 0.01 mm.
• Infinite resolution
• No variation of electrical signal outside theoretical electrical stroke
• Displacement speed up to:
4 m/s PK L version
10 m/s PK H version
• Working temperature: -30…+100°C
• Electrical connections:
PK M 4-pole connector to standard DIN43650 ISO4400
PK B 5-pole connector (DIN43322)
• Life duration: > 25×10 6 meters or > 100×10 6 operations, whichever is the smaller (within C.E.U.)
• Grade of protection IP40 |
 |
IK1A Displacement Transducer Contactless Measurement Using Magnetostriction (ANALOG OUTPUT)
|
Main features :
• Absolute type transducer
• Displacements from 100 to 4000mm
• Working temperature range: -40…70°C
• Vibration resistant (DIN IEC68T2/6 12g)
• Rod, nipple, hexagonal flange AISI 316
• IP67 Protection
• EMI CE compatible (EN 50081-2 50082-1)
• Power supply 24Vdc ±20%
• Optional galvanic isolation between the power supply and the output
|
 |
MK1D Displacement Transducers Contactless Measurement Using Magnetostriction (DIGITAL OUTPUT)
| Main features :
• Absolute type transducer
• Displacements from 100 to 4000mm
• Working temperature range: -40…70°C
• Vibration resistant (DIN IEC68T2/6 12g)
• Low profile and reduced dimensions
• IP67 Protection
• EMI CE compatible (EN 50081-2 50082-1)
• Power supply 24Vdc ±20%
• Optional galvanic isolation between the power supply and the output |
 |
|
|
|
 
|
|
back to top